Fire Resistant FTP CAT3 Data Cables

Original
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Shandong
Validity to: Long-term effective
Last update: 2017-07-09 23:44
Browse the number: 74
inquiry
Company Profile
 
 
Product details

Supplying you with customized fire resistant ftp cat3 data cables, it is one of the reliable fire resistant ftp cat3 data cables manufacturers and suppliers, welcome to wholesale our products at good price from our factory.

Fire resistant FTP Cat3 Data Cables

FR-CAT3FTP 4P22FR

Application:

The cables are desgined for structure wiring, compatible with all known connection systems according to EN 50173. Based on the design for structured wiring (found in IEC 61156 and BS EN 50288), this cable brings together high frequency data transmission and circuit integrity in a one pair, two pair and four pair cable that will continue to transmit data even when being directly attacked by fire.

STANDARDS:

Basic design to EN 50173

VOLTAGE RATING:

60V

FIRE PERFORMANCE

Circuit Integrity

IEC 60331-23; BS 6387 CWZ; DIN VDE 0472-814(FE180);

CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame Retardance (Single Vertical

Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;

VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation

(Vertically-mounted bundled wires

& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

CABLE CONSTRUCTION

Conductors: Plain annealed copper wire, sized 0.64mm and solid according to IEC(EN) 60228 class1.

Insulation: PE wrapping with fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize

crosstalk. Two-pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layer.

Overall Screen: Aluminum/polyester tape with tinned copper drain wire

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH

compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

COLOUR CODE

Sheath Colour: Red, white or black

Physical AND THERMAL PROPERTIES

Temperature range during operation (fixed state): -20℃ - +90℃

Temperature range during installation (mobile state): -5℃ - +50℃

Minimum bending radius: 8 x Overall Diameter

Electrical Properties

Characteristic Impedance

100 Ohm±15%

Nominal Velocity Of Propagation (NVP)

69%

Max. Dc Resistance

5.8 Ohm/100m

Max. Resistance Unbalance

5%

Max. Propagation Delay Skew

30 ns/100m

Max. Propagation Delay

536 ns/100m@100 mhz

Max. Pulling Load

80N


FREQ (MHz)

NEXT(dB/100m)

Minmum Value/Typical

Value/Standard Value

IL (dB/100m)

SRL(dB/100m)

Minmum Value/Typical

Value/Standard Value

1

43.0/48.0/41.0

2.6

13.0/16.0/12.0

4

34.0/38.0/32.0

5.6

13.0/16.0/12.0

8

29.0/33.0/26.0

8.5

13.0/16.0/12.0

10

28.0/33.0/26.0

9.8

13.0/16.0/12.0

16

25.0/30.0/23.0

13.1

11.0/14.0/10.0

CONSTRUCTION PARAMETERS

Cable Code

Nominal Insulation Thickness

Nominal Overall Diameter

Approx.

Weight


mm

mm

kg/km

FR-CAT3FTP1P22FR

0.25

6.8

48

FR-CAT3FTP2P22FR

0.25

8.1

97

FR-CAT3FTP4P22FR

0.25

10.4

122